  • XBR-G6MIDR12PTPOD-32G software license
    Brocade XBR-G6MIDR12PTPOD-32G BR-MIDRMFEB-01-Z software license for HD-G620-24-32G switch

    Brand Brocade License PN XBR-G6MIDR12PTPOD-32G License Inside PN  BR-MIDRMFEB-01-Z Place of origin Malaysia Form Factor F/S Inside SFP:8pcs 32G 850nm SW Active Brocade HD-G630-48-32G switch Low End Case Temperature (°C) 0°C High End Case Temperature (°C) 70°C Diagnostics Digital Transmitter VCSEL Receiver PIN Voltage Supply 3.3--5v Connector Dual LC Warranty 1 year Condition new DDMI Yes Time of delivery  Within 24 hours Package Brocade original package

    read more
  • G720-64-32G-F Fiber Optical Switch
    24/64 ports Brocade G720 Switch G720-64-32G-F Fiber Optical Switch

    The Brocade G720 Switch is a Gen 7 switch with 64 ports in an ultra-dense 1U design. Delivering unmatched 64G performance and 50% lower latency compared to the previous generation, this switch delivers a fixed-port building block designed to maximize the performance of flash and NVMe environments to meet demanding workloads. With Brocade Gen 7 technology, the Brocade G720 delivers far more than just speed and latency improvements. It can eliminate the pain of managing your data center, with autonomous SAN technology to deliver a network that can self-learn, self-optimize, and self-heal without intervention.

    read more
  • QDD-400G-ZRP-S
    Compatible QDD-400G-ZRP-S 400G ZRP Optical Transceivers

    Product Description This MSA compliant QSFP-DD transceiver provides 400GBase-ZR Open ZR+ throughput over Single-mode fiber (SMF) using a coherent wavelength and using an LC connector. It is built to MSA standards and is uniquely serialized and data-traffic and application tested to ensure that they will integrate into your network seamlessly. Digital optical monitoring (DOM) support is also present to allow access to real-time operating parameters. This transceiver is Trade Agreements Act (TAA) compliant. We stand behind the quality of our products and proudly offer a limited lifetime warranty. ProLabs’ transceivers are RoHS compliant and lead-free. TAA refers to the Trade Agreements Act (19 U.S.C. & 2501-2581), which is intended to foster fair and open international trade. TAA requires that the U.S. Government may acquire only “U.S. – made or designated country end products.

    read more
  • SFP 1.25G FR 15km
    Compatible Mikrotik XS+2733LC15D SFP 1.25G FR Single Mode 1270nm+ 1330nm 15km Optical Transceivers

    Kit contains two SFP+ modules that can be used as a pair to achieve operating data rate up to 25 Gbps for distances up to 15km on a single optical cable. SFP/ SFP+/ SFP28 Units are tested and compatible with RB260GS,RB2011LS, RB2011LS-IN, RB2011UAS-IN, RB2011UAS-RM, RB2011UAS-2HnD, RB2011UAS-2HnD-IN, and CCR1036-12G-4S. Units are compatible with non-MikroTik SFP devices as well. Details Product code XS+2733LC15D Connector Single LC UPC Data Rate 1G / 10G / 25G Distance 15 km Format SFP / SFP+ / SFP28 Mode Single mode Wavelength 1270nm + 1330nm

    read more
  • QSFP+ 10G SR 15km
    Compatible Mikrotik XS+2733LC15D 10G QSFP+ SR Optical Transceivers

    Kit contains two SFP+ modules that can be used as a pair to achieve operating data rate up to 25 Gbps for distances up to 15km on a single optical cable. SFP/ SFP+/ SFP28 Optical Transceivers

    read more
  • BR6505-24-8G-R/BR6505-24-16GR/BR6505-24-16GR/6505-24-0-R
    12/24 Ports Compatible Brocade BR6510 Gen 5 Fiber Channel 1U Switch BR6510-24-8G-R/BR6510-24-16GR/BR6510-24-16GR/6505-24-0-R Fiber Optical Switch Suitable For 57-1000117-01/57-1000027-01/57-0000080-01/57-0000088-01/57-0000089-01

    12/24 Ports Compatible Brocade BR6510 Gen 5 Fiber Channel 1U Switch BR6510-24-8G-R/BR6510-12-8GR/BR6510-24-8GR Fiber Optical Switch Suitable For 57-1000117-01/57-1000027-01/57-0000080-01/57-0000088-01/57-0000089-01/57-1000487-01/57-0000089-01/57-1000488-01/57-1000262-01/57-1000489-01/XBR-000458/XBR-000258/XBR-000499/XBR-000498

    read more
Cabling Options for 40G QSFP SR4 and 40G QSFP BiDi Transceivers

2023 / 12 / 19

40G QSFP SR4 and 40G QSFP BiDi at a Glance

Before we go any further, it’s better to first obtain some basic information about 40G QSFP SR4 and 40G QSFP BiDi transceiver. As they both used to support short-range (SR) 40G connectivity, the major difference lies in the protocols, namely the way to achieve data transmission for 40G application. 40G QSFP SR4 operates over MMF ribbon with MPO connectors, utilizing 4 parallel fiber pairs (8 fiber strands) at 10Gbps each for a total of 40Gbps full duplex.

40g qsfp sr4

40G QSFP BiDi uses the same 10-Gbps electrical lanes, however, they are combined in the optical outputs. Thus requiring two fibers with a LC connector interface. Each fiber simultaneously transmits and receives 20-Gbps traffic at two different wavelengths. Which means that 40G QSFP BiDi module converts four channels each of 10Gbps transmit and receive signals to two bidirectional channels of 20Gbps signals. The connection can reach 100 m on OM3 MMF or 150 m on OM4 MMF, which is the same as 40-Gbps SR4.

40g qsfp bidi

Cabling Solutions for 40G QSFP SR4 and 40G QSFP BiDi Transceivers

Whether for 40G QSFP SR4 or BiDi Transceivers, there basically exist three cabling approaches: direct connection, interconnection and cross-connection. This section respectively illustrates the three approaches for 40G transceiver cabling.

Options for 40G QSFP SR4 Transceiver

40G SR4 operates over 12-fiber strands terminated by MPO-12 connectors, 8-fiber strands carry traffic and 4 are unused. So there are three cabling options for parallel 40G QSFP SR4 connectivity:

  • Solution 1: No conversion and uses traditional 12-fiber MTP connectivity.
  • Solution 2: Use conversion module. Converts two 12 fiber links to three 8 fiber links through a conversion patch panel.
  • Solution 3: Converts two 12-fiber links to three 8-fiber links through a conversion assembly and standard MTP patch panels.

Here we offer cabling options for parallel 40G QSFP SR4 transceiver based on these three solutions.

Scenario One: Direct Connection for 40G QSFP SR4 Transceiver

Direct connection between two parallel optics 40G Ethernet transceiver, a Type-B (key up to key up) MTP patch cable should be used. With fiber 1 on one end goes to fiber 12 on the other end, this reverse fiber positioning ensures the signal to flow from transmission on one end of the link to reception on the other end. The picture below shows an MTP patch cable directly connects two switch ports.

40g-QSFP-SR4 direct connection

Scenario Two: Interconnection for 40G QSFP SR4 Transceiver

The most basic structured cabling solution is an interconnect. The following picture shows several interconnect approaches with various patch panel options.

a. The 2×3 conversion modules allow 100% fiber utilization and constitute the most commonly deployed method. It also greatly reduced jumper complexity. The female to female Type-B polarity cable here is used to directly connect two parallel optic transceivers. That same jumper is used on both ends of the interconnect link, thus eliminating concerns about correct pinning.

b. The same trunk used in method a is adopted, but the jumper type is now male to female Type-B polarity. Thus, when you install the MTP patch cable, you would install the male end in the patch panel, and you would install the female end in the electronics.

c. This combined solution might be deployed when cabling between a spine switch, where the module is placed, and a ToR leaf switch, where the conversion harness and MTP adapter panel are located.

40g-QSFP-SR4 interconnection

Scenario Three: Cross-Connection for 40G QSFP SR4 Transceiver

The picture below shows two cross-connection link designs for cabling a 40G QSFP SR4 transceiver.

a. This link design shows a conversion module example, which again is the most common and preferred method. All the three jumpers in the link are female to female MTP patch cable with Type-B polarity. Thus, in a conversion module deployment, only one jumper type is used for a direct-connect, interconnect, or cross-connect cabling scenario.

b. Standard MTP patch panels are deployed in this method. Here the MTP patch cables at the electronics are female (into the electronics) to male (into the patch panel), although the patch cords at the cross-connect are male-to-male going into the patch panel.

40g-QSFP-SR4 cross-connection

Options for 40G QSFP BiDi Transceiver

Cabling for 40G QSFP BiDi transceiver is relatively easy. Three methods are presented here.

Scenario One: Direct Connection for 40G QSFP BiDi Transceiver

In an unstructured cabling system, devices are directly connected with fiber optic cable. This direct-attachment design can be used to connect devices within short distances in a data center network. Direct connection between two 40-Gbps devices can be provided by MMF cables with QSFP BiDi transceivers at two ends.

40g-QSFP-SR bidi direct connection

Scenario Two: Interconnection for 40G QSFP BiDi Transceiver

When it comes to structured cabling, more permanent links should be considered. The interconnection link between two 40G bidirectional ports basically consists of an MTP trunk, MTP module cassettes and LC fiber patch cables. Future migration can be achieved simply by changing the patch panels on each end, without the need to disrupt the cabling infrastructure.

40g-QSFP-SR bidi interconnection

Scenario Three: Cross-Connection for 40G QSFP BiDi Transceiver

The cross-connection design involves two structured cabling links, which connect two switches via a centralized cross-connect. This design delivers much flexibility when new equipment need to be installed: only patch cables are required to make the connection from the equipment to the patch panels.

40g-QSFP-SR bidi cross-connection

Conclusion

Judging from the cabling solutions for 40G QSFP SR4 and BiDi transceivers, it is clear that QSFP BiDi transceivers provide immense flexibility and simplicity compared to parallel 40G QSFP SR4 transceivers, while removing cost barriers for migration from 10G to 40G in data center networks. However, the main advantage of 40G SR4 transceiver over 40G BiDi transceiver is the reach. Hope what we discussed in the article could help make an informed decision.